Error report for Modelica.Fluid.Examples.DrumBoiler.DrumBoiler

Compiler arguments:
-log=i,w|xml|stderr -opt=max_n_proc:1,c_compiler:gcc -target=me -version=1.0 -platform=win32 -out=. -modelicapath=C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL Modelica.Fluid.Examples.DrumBoiler.DrumBoiler
Current working directory:
C:\Users\tove_021
Compiler version: 1.17.x
Java version: 1.7.0_15
MODELICAPATH =
JAVA_HOME = C:\JModelica.org-SDK-1.11\Java\jdk1.7.0_15
JMODELICA_HOME = C:\JModelica.org-SDK-1.11\install
======= Compiling model =======
Checking for errors...
MODELICAPATH = C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL
extra_lib_dirs =
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\ComplexBlocks.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\ComplexMath.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Constants.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Electrical\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Icons.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Magnetic\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Math\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Mechanics\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\SIunits.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\StateGraph.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Thermal\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Utilities\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Dissipation.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Fittings.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Icons.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Interfaces.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Machines.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Pipes.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Sensors.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Sources.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\System.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Types.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Utilities.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Valves.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Vessels.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\AST_BatchPlant.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\BranchingDynamicPipes.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\ControlledTankSystem.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\DrumBoiler.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\Explanatory.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\HeatExchanger.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\HeatingSystem.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\IncompressibleFluidNetwork.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\InverseParameterization.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\NonCircularPipes.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\PumpingSystem.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\Tanks.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\TraceSubstances.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Thermal\FluidHeatFlow.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Thermal\HeatTransfer.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\Continuous.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\Discrete.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\Icons.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\Interaction.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\Interfaces.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\Logical.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\Math.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\MathBoolean.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\MathInteger.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\Nonlinear.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\Routing.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\Tables.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Blocks\Types.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\Air\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\CompressibleLiquids.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\IdealGases\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\Incompressible.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\R134a.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\Water\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\Water\IF97_Utilities.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\ModelicaServices\package.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Math\BooleanVectors.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Math\isPowerOf2.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Math\Nonlinear.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Utilities\Examples.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Utilities\Files.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Utilities\Internal.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Utilities\Streams.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Utilities\Strings.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Utilities\System.mo
Reading file: C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Utilities\Types.mo
Warning at line 225, column 49, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Examples\DrumBoiler.mo':
The component allowFlowReversal is declared multiple times and can not be verified to be identical to other declaration(s) with the same name.
Warning at line 794, column 14, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Sources.mo':
The cardinality() function-like operator is deprecated, and will be removed in a future version of Modelica
Warning at line 849, column 14, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Sources.mo':
The cardinality() function-like operator is deprecated, and will be removed in a future version of Modelica
Warning at line 7, column 36, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Utilities.mo':
String arguments in functions are only partially supported
Warning at line 8, column 28, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Utilities.mo':
String arguments in functions are only partially supported
Warning at line 12, column 29, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Utilities.mo':
String arguments in functions are only partially supported
Warning at line 15, column 36, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Fluid\Utilities.mo':
String arguments in functions are only partially supported
Warning at line 4427, column 64, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\package.mo':
String parameters are only partially supported
Warning at line 4428, column 76, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\package.mo':
String parameters are only partially supported
Warning at line 4430, column 96, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\package.mo':
String parameters are only partially supported
Warning at line 7191, column 38, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\package.mo':
String parameters are only partially supported
Warning at line 7193, column 66, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\package.mo':
String parameters are only partially supported
Warning at line 7195, column 64, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\package.mo':
String parameters are only partially supported
Warning at line 7197, column 70, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Media\package.mo':
String parameters are only partially supported
Warning at line 126, column 36, in file 'C:\JModelica.org-SDK-1.11\install\ThirdParty\MSL\Modelica\Utilities\Streams.mo':
String arguments in functions are only partially supported
Flattening model...
Applying transformation: enableIfEquationElimination...
Applying transformation: genBindingAssignments...
Applying transformation: scalarize...
Applying transformation: MakeReinitedVarsStates...
Applying transformation: enableIfEquationElimination...
Applying transformation: enableStreamsRewrite...
Applying transformation: extractEventGeneratingExps...
Applying transformation: transformAlgorithms...
Applying transformation: enableWhenClauseRewrite...
Applying transformation: extractSampleExpressions...
Applying transformation: genInitArrayStatements...
Applying transformation: FunctionInliningIfSet...
Applying transformation: setFDerivativeVariables...
Applying transformation: addFPreVariables...
Applying transformation: enableIfEquationRewrite...
Applying transformation: aliasEliminationIfSet...
Applying transformation: variabilityPropagationIfSet...
Applying transformation: aliasEliminationIfSet...
Applying transformation: enableExpandedInStreamRewrite...
Applying transformation: evaluateAsserts...
Applying transformation: enableSemiLinearRewrite...
Applying transformation: eliminateEqualSwitches...
Applying transformation: genInitialEquations...
Applying transformation: setFDerivativeVariablesPreBLT...
Applying transformation: propagateNonFixedParameters...
Applying transformation: indexReduction...
Applying transformation: aliasEliminationIfSet...
Applying transformation: setFDerivativeVariables...
States:
Real controller.x(start = controller.x_start) "State of block"
Modelica.SIunits.Volume evaporator.V_l(start = evaporator.V_l_start,stateSelect = StateSelect.prefer) "volumes of liquid phase"
Modelica.Media.Water.WaterIF97_ph.AbsolutePressure evaporator.p(start = evaporator.p_start,stateSelect = StateSelect.prefer,nominal = 1000000.0,min = 611.657,max = 1.0E8) "pressure inside drum boiler"

Applying transformation: LateFunctionInliningIfSet...
Applying transformation: commonSubexpressionEliminationIfSet...
Applying transformation: addFPreVariables...
Applying transformation: aliasEliminationIfSet...
Applying transformation: sortDependentParameters...
Applying transformation: addRuntimeOptionParameters...
Applying transformation: computeMatchingsAndBLT...
Warning in flattened model:
Iteration variable "der(evaporator.V_v)" is missing start value!
Warning in flattened model:
Iteration variable "der(evaporator.p)" is missing start value!
Generating code...
====== Model compiled successfully =======

Compiling...
... elapsed time: 12.75s
Loading...
States: ['controller.x', 'evaporator.V_l', 'evaporator.p']
Nominals: [1.0, 1.0, 1000000.0]
... elapsed time: 0.18s
Found solver method None...
... ncp = 2000
... using CVode
Initializing...
Start Time: 0.0
Stop Time: 5400.0
Tolerance: 1e-06
... elapsed time: 0.00s
Simulating...
Final Run Statistics: Modelica.Fluid.Examples.DrumBoiler.DrumBoiler

Number of steps : 2031
Number of function evaluations : 2084
Number of Jacobian evaluations : 39
Number of function eval. due to Jacobian eval. : 117
Number of error test failures : 5
Number of nonlinear iterations : 2056
Number of nonlinear convergence failures : 0
Number of state function evaluations : 2078
Number of state events : 6

Solver options:

Solver : CVode
Linear multistep method : BDF
Nonlinear solver : Newton
Linear solver type : DENSE
Maximal order : 5
Tolerances (absolute) : [ 1.00000000e-06 1.00000000e-06 1.00000000e+00]
Tolerances (relative) : 1e-06

Simulation interval : 0.0 - 5400.0 seconds.
Elapsed simulation time: 4.08879380919 seconds.
... elapsed time: 4.31s