Error report for Modelica.Fluid.Examples.AST_BatchPlant.Test.TankWithEmptyingPipe2

Compiler arguments:
-log=i,w|xml|stderr -opt=max_n_proc:1 -target=me -version=1.0 -platform=win32 -out=. -modelicapath=C:\JModelica.org-1.16\install\ThirdParty\MSL c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica Modelica.Fluid.Examples.AST_BatchPlant.Test.TankWithEmptyingPipe2
Current working directory:
C:\Users\tove_021
Compiler version: 1.16
Java version: 1.7.0_15
MODELICAPATH =
JAVA_HOME = C:\JModelica.org-1.16\Java\jre7
JMODELICA_HOME = C:\JModelica.org-1.16\install
======= Compiling model =======
Parsing c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\package.mo...
Checking for errors...
MODELICAPATH = C:\JModelica.org-1.16\install\ThirdParty\MSL
extra_lib_dirs =
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\ComplexBlocks.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\ComplexMath.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Constants.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Electrical\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Icons.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Magnetic\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Math\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Mechanics\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Media\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\SIunits.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\StateGraph.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Thermal\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Utilities\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Dissipation.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Fittings.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Icons.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Interfaces.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Machines.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Pipes.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Sensors.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Sources.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\System.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Types.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Utilities.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Valves.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Vessels.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\AST_BatchPlant.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\BranchingDynamicPipes.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\ControlledTankSystem.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\DrumBoiler.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\Explanatory.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\HeatExchanger.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\HeatingSystem.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\IncompressibleFluidNetwork.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\InverseParameterization.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\NonCircularPipes.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\PumpingSystem.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\Tanks.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Examples\TraceSubstances.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Media\Air\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Media\CompressibleLiquids.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Media\IdealGases\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Media\Incompressible.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Media\R134a.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Media\Water\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Media\Water\IF97_Utilities.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\Continuous.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\Discrete.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\Icons.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\Interaction.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\Interfaces.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\Logical.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\Math.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\MathBoolean.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\MathInteger.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\Nonlinear.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\Routing.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\Tables.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Blocks\Types.mo
Reading file: C:\JModelica.org-1.16\install\ThirdParty\MSL\ModelicaServices\package.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Utilities\Examples.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Utilities\Files.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Utilities\Internal.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Utilities\Streams.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Utilities\Strings.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Utilities\System.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Utilities\Types.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Thermal\FluidHeatFlow.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Thermal\HeatTransfer.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Math\BooleanVectors.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Math\isPowerOf2.mo
Reading file: c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Math\Nonlinear.mo
Warning at line 1015, column 92, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Pipes.mo':
The component allowFlowReversal is declared multiple times and can not be verified to be identical to other declaration(s) with the same name.
Warning at line 1020, column 107, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Pipes.mo':
The component momentumDynamics is declared multiple times and can not be verified to be identical to other declaration(s) with the same name.
Warning at line 1023, column 109, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Pipes.mo':
The component m_flow_start is declared multiple times and can not be verified to be identical to other declaration(s) with the same name.
Warning at line 1219, column 75, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Pipes.mo':
The parameter pipe1.flowModel.dp_nominal does not have a binding expression
Warning at line 1219, column 75, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Pipes.mo':
The parameter pipe2.flowModel.dp_nominal does not have a binding expression
Warning at line 1229, column 15, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Pipes.mo':
The parameter pipe1.flowModel.dp_small does not have a binding expression
Warning at line 1229, column 15, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Pipes.mo':
The parameter pipe2.flowModel.dp_small does not have a binding expression
Warning at line 794, column 14, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Sources.mo':
The cardinality() function-like operator is deprecated, and will be removed in a future version of Modelica
Warning at line 7, column 36, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Utilities.mo':
String arguments in functions are only partially supported
Warning at line 8, column 28, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Utilities.mo':
String arguments in functions are only partially supported
Warning at line 12, column 29, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Utilities.mo':
String arguments in functions are only partially supported
Warning at line 15, column 36, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Fluid\Utilities.mo':
String arguments in functions are only partially supported
Warning at line 4426, column 64, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Media\package.mo':
String parameters are only partially supported
Warning at line 4427, column 76, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Media\package.mo':
String parameters are only partially supported
Warning at line 4429, column 96, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Media\package.mo':
String parameters are only partially supported
Warning at line 126, column 36, in file 'c:\JModelica.org-1.16\install\ThirdParty\MSL\Modelica\Utilities\Streams.mo':
String arguments in functions are only partially supported
Flattening model...
Applying transformation: enableIfEquationElimination...
Applying transformation: genBindingAssignments...
Applying transformation: scalarize...
Applying transformation: MakeReinitedVarsStates...
Applying transformation: enableIfEquationElimination...
Applying transformation: enableStreamsRewrite...
Applying transformation: extractEventGeneratingExps...
Applying transformation: transformAlgorithms...
Applying transformation: enableWhenClauseRewrite...
Applying transformation: extractSampleExpressions...
Applying transformation: genInitArrayStatements...
Applying transformation: FunctionInliningIfSet...
Applying transformation: setFDerivativeVariables...
Applying transformation: addFPreVariables...
Applying transformation: enableIfEquationRewrite...
Applying transformation: aliasEliminationIfSet...
Applying transformation: variabilityPropagationIfSet...
Applying transformation: aliasEliminationIfSet...
Applying transformation: evaluateAsserts...
Applying transformation: enableSemiLinearRewrite...
Applying transformation: eliminateEqualSwitches...
Applying transformation: genInitialEquations...
Applying transformation: setFDerivativeVariablesPreBLT...
Applying transformation: propagateNonFixedParameters...
Applying transformation: indexReduction...
Applying transformation: aliasEliminationIfSet...
Applying transformation: setFDerivativeVariables...
States:
Modelica.SIunits.Length tank1.level(stateSelect = StateSelect.prefer,start = tank1.level_start) "Fluid level in the tank"
Modelica.Media.Water.ConstantPropertyLiquidWater.Temperature tank1.medium.T(start = tank1.T_start,stateSelect = StateSelect.prefer) "Temperature of medium"

Applying transformation: LateFunctionInliningIfSet...
Applying transformation: addFPreVariables...
Applying transformation: aliasEliminationIfSet...
Applying transformation: sortDependentParameters...
Applying transformation: addRuntimeOptionParameters...
Applying transformation: computeMatchingsAndBLT...
Generating code...
====== Model compiled successfully =======

Compiling...
... elapsed time: 8.70s
Loading...
States: ['tank1.level', 'tank1.medium.T']
Nominals: [1.0, 300.0]
... elapsed time: 0.16s
Found solver method None...
... ncp = 2000
... using CVode
Initializing...
Start Time: 0.0
Stop Time: 120.0
Tolerance: 1e-06
... elapsed time: 0.00s
Simulating...
Final Run Statistics: Modelica.Fluid.Examples.AST_BatchPlant.Test.TankWithEmptyingPipe2

Number of steps : 2007
Number of function evaluations : 2029
Number of Jacobian evaluations : 36
Number of function eval. due to Jacobian eval. : 72
Number of error test failures : 0
Number of nonlinear iterations : 2009
Number of nonlinear convergence failures : 0
Number of state function evaluations : 2036
Number of state events : 4

Solver options:

Solver : CVode
Linear multistep method : BDF
Nonlinear solver : Newton
Linear solver type : DENSE
Maximal order : 5
Tolerances (absolute) : [ 1.00000000e-06 3.00000000e-04]
Tolerances (relative) : 1e-06

Simulation interval : 0.0 - 120.0 seconds.
Elapsed simulation time: 0.818003229609 seconds.
... elapsed time: 1.00s