Error report for Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut

Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\Thermal\FluidHeatFlow.mo':
At line 2278, column 91:
The parameter pipe1.k does not have a binding expression
Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\Thermal\FluidHeatFlow.mo':
At line 2278, column 91:
The parameter pipe2.k does not have a binding expression
Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\Thermal\FluidHeatFlow.mo':
At line 2278, column 91:
The parameter pipe3.k does not have a binding expression
Warning: in file 'C:\Users\tove_021\AppData\Local\Temp\jmc1957057615588190279out\sources\Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut.mof':
At line 0, column 0:
Iteration variable "pipe1.flowPort_a.m_flow" is missing start value!
Warning: in file 'C:\Users\tove_021\AppData\Local\Temp\jmc1957057615588190279out\sources\Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut.mof':
At line 0, column 0:
Iteration variable "pipe1.flowPort_b.p" is missing start value!
Compiling...
... elapsed time: 4.16s
Loading...
... elapsed time: 0.10s
Initializing...
... elapsed time: 0.00s
Simulating...
Final Run Statistics: Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut

Number of steps : 67
Number of function evaluations : 131
Number of Jacobian evaluations : 10
Number of function eval. due to Jacobian eval. : 50
Number of error test failures : 0
Number of nonlinear iterations : 91
Number of nonlinear convergence failures : 0
Number of state function evaluations : 146
Number of state events : 9

Solver options:

Solver : CVode
Linear multistep method : BDF
Nonlinear solver : Newton
Maximal order : 5
Tolerances (absolute) : 0.0003
Tolerances (relative) : 0.0001

Simulation interval : 0.0 - 2.0 seconds.
Elapsed simulation time: 0.696584360907 seconds.
... elapsed time: 0.76s