Error report for Modelica.Electrical.MultiPhase.Examples.TestSensors

Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\SIunits.mo':
At line 1137, column 40:
Assuming 'each' for the attribute quantity
Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\SIunits.mo':
At line 1138, column 48:
Assuming 'each' for the attribute unit
Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\SIunits.mo':
At line 1139, column 21:
Assuming 'each' for the attribute min
Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\SIunits.mo':
At line 1140, column 16:
Assuming 'each' for the attribute start
Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\SIunits.mo':
At line 1141, column 21:
Assuming 'each' for the attribute nominal
Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\SIunits.mo':
At line 1142, column 20:
Assuming 'each' for the attribute displayUnit
Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\SIunits.mo':
At line 1224, column 31:
Assuming 'each' for the attribute quantity
Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\SIunits.mo':
At line 1224, column 64:
Assuming 'each' for the attribute unit
Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\SIunits.mo':
At line 1239, column 33:
Assuming 'each' for the attribute quantity
Warning: in file 'C:\JModelica.org-1.14\install\ThirdParty\MSL\Modelica\SIunits.mo':
At line 1239, column 68:
Assuming 'each' for the attribute unit
Warning: in file 'C:\Users\tove_021\AppData\Local\Temp\jmc5643977105698720271out\sources\Modelica.Electrical.MultiPhase.Examples.TestSensors.mof':
At line 0, column 0:
The variable currentQuasiRMSSensor.m is declared multiple times and can not be verified to be identical to other declaration(s) with the same name.
Warning: in file 'C:\Users\tove_021\AppData\Local\Temp\jmc5643977105698720271out\sources\Modelica.Electrical.MultiPhase.Examples.TestSensors.mof':
At line 0, column 0:
The variable voltageQuasiRMSSensor.m is declared multiple times and can not be verified to be identical to other declaration(s) with the same name.
Compiling...
... elapsed time: 5.56s
Loading...
... elapsed time: 0.10s
Initializing...
... elapsed time: 0.00s
Simulating...
Final Run Statistics: Modelica.Electrical.MultiPhase.Examples.TestSensors

Number of steps : 188
Number of function evaluations : 222
Number of Jacobian evaluations : 4
Number of function eval. due to Jacobian eval. : 8
Number of error test failures : 4
Number of nonlinear iterations : 218
Number of nonlinear convergence failures : 0
Number of state function evaluations : 189

Solver options:

Solver : CVode
Linear multistep method : BDF
Nonlinear solver : Newton
Maximal order : 5
Tolerances (absolute) : 1e-06
Tolerances (relative) : 0.0001

Simulation interval : 0.0 - 0.1 seconds.
Elapsed simulation time: 0.117032835908 seconds.
... elapsed time: 0.23s