Error report for Modelica.Thermal.HeatTransfer.Examples.Motor

Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo':
At line 2366, column 80:
String parameters are only partially supported
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo':
At line 2369, column 76:
String parameters are only partially supported
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo':
At line 2392, column 61:
The parameter lossTable.t_min does not have a binding expression
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo':
At line 2394, column 48:
The parameter lossTable.t_max does not have a binding expression
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo':
At line 2410, column 32:
The parameter lossTable.tableOnFileRead does not have a binding expression
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo':
At line 2415, column 38:
The parameter tableID does not have a binding expression
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo':
At line 2428, column 38:
The parameter tableID does not have a binding expression
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo':
At line 2447, column 38:
The parameter tableID does not have a binding expression
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo':
At line 2478, column 38:
The parameter tableID does not have a binding expression
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo':
At line 2489, column 38:
The parameter tableID does not have a binding expression
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Sources.mo':
At line 2500, column 38:
The parameter tableID does not have a binding expression
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Types.mo':
At line 117, column 38:
String arguments in functions are only partially supported
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Types.mo':
At line 118, column 42:
String arguments in functions are only partially supported
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Types.mo':
At line 124, column 62:
The parameter externalCombiTimeTable does not have a binding expression
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Blocks\Types.mo':
At line 141, column 38:
The parameter externalCombiTimeTable does not have a binding expression
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Utilities\Strings.mo':
At line 6, column 36:
String arguments in functions are only partially supported
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Utilities\Strings.mo':
At line 141, column 36:
String arguments in functions are only partially supported
Warning: in file 'C:\JModelica.org-1.13\install\ThirdParty\MSL\Modelica\Utilities\Strings.mo':
At line 1147, column 38:
String arguments in functions are only partially supported
Compiling...
... elapsed time: 3.17s
Loading...
... elapsed time: 0.09s
Initializing...
... elapsed time: 0.00s
Simulating...
Final Run Statistics: Modelica.Thermal.HeatTransfer.Examples.Motor

Number of steps : 269
Number of function evaluations : 476
Number of Jacobian evaluations : 24
Number of F-eval during Jac-eval : 48
Number of event function evaluations : 316
Number of error test failures : 4
Number of Newton iterations : 380
Number of Newton convergence failures : 0
Number of State-Events : 24

Solver options:

Solver : CVode
Linear multistep method : BDF
Nonlinear solver : Newton
Maximal order : 5
Tolerances (absolute) : 0.0003
Tolerances (relative) : 0.0001

Simulation interval : 0.0 - 7200.0 seconds.
Elapsed simulation time: 0.0817174876411 seconds.
... elapsed time: 0.11s